Before simulating a 100% renewable fleet, the model has to reproduce today's system. This page compares the generation of the simulated "real fleet" with what was measured, source by source, in the eight largest countries and for the whole modelled Europe. Gaps are published as they are, including those beyond the tolerance.
Loading…
What is compared. The "real fleet" scenario: plants existing at the end of 2025, actual demand and weather, and least-cost dispatch. No measured generation of the day is fed into the calculation.
What the model borrows from measurements. Availability of nuclear (maximum observed over the previous seven days), recent hydro inflows, and the monthly level of bioenergy and other fossil generation (previous year). These are known the day before, not the result of the day.
Availability of hard coal, lignite and gas. It comes from official sources, never from observed generation: outages declared by operators to ENTSO-E, German plants held in reserve outside the market (Bundesnetzagentur list), and the scheduled capacity published the day before by the Polish grid operator PSE. These rules apply to recent days; the 2025 yearly comparison only removes the German plants outside the market.
Known limits. Solar and wind depend on the weather calibration, still biased in some countries. The fleet is that of end 2025: a reactor closed during the year (Belgium) is missing for the whole year. The Netherlands under-report coal and solar. The yearly comparison replays the daily engine day by day, without sight of the following days.
Sources. Ember, Monthly electricity data (CC BY 4.0). ENTSO-E Transparency Platform, generation per production type, outages and installed capacity. Elexon, BSC Open Data Licence. Bundesnetzagentur, Kraftwerksliste. PSE S.A., daily coordination plan. Full method: Method page.